AUTO SWITCH
MINI AUTOSWITCH (WTF)
- Automatically start the Motor
- Single Phasing Protection
- Reverse Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Suitable for DOL & FASD Starter
- LED indications
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Resetting | Auto Reset |
Enclosure | ABS Material |
- Pump sets of Farms, Rivers and Wells
- Suitable for DOL and FASD starter.
AUTO SWITCH
AUTOSWITCH (WTF)
- Automatically start the Motor
- Single Phasing Protection
- Reverse Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Suitable for DOL & FASD Starter
- LED indications
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Resetting | Auto Reset |
Enclosure | ABS Material |
- Pump sets of Farms, Rivers and Wells
- Suitable for DOL and FASD starter.
AUTO SWITCH
AUTOSWITCH (WTF-RF)
- Provide Auto Correct Phase Sequence System
- Automatically start the Motor
- Single Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Suitable for DOL & FASD Starter
- Each Phase LED indications
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Switching Device | Relay |
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Reset Mode | Auto |
Enclosure | Engineering Grade ABS virgin material |
- Pump sets of Farms, Rivers and Wells.
- Suitable for DOL and FASD starter.
AUTO SWITCH
AUTOSWITCH (WTS-RF)
- Microcontroller based Technology
- Specially for Oil Filled Bentex Starter (9 wires)
- Provide Auto Correct Phase Sequence System
- Automatically start the Motor
- Single Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Each Phase LED indications
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Switching Device | Relay |
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Reset Mode | Auto |
Enclosure | ABS Virgin Material |
- Pump sets of Farms, Rivers and Wells
- Oil Filled Bentex Starter Of Agriculture Pump.
AUTO SWITCH
AUTOSWITCH (WDS)
- Specially for Semi Automatic Star Delta Starter
- Automatically start the Motor
- Single Phasing Protection
- Reverse Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- LED indications
- Auto / manual switch
System Voltage | 415VAC instead of 230VAC |
---|---|
Switching Device | Relay |
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Reset Mode | Auto |
Enclosure | ABS Material |
- Pump sets of Farms, Rivers and Wells
- Suitable for Semi Automatic Star Delta Starter
AUTO SWITCH
AUTOSWITCH (WDS-RF)
- Specially for Semi Automatic Star-Delta Starter
- Provide Auto Correct Phase Sequence System
- Automatically start the Motor
- Single Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Each Phase LED indications
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Switching Device | Relay |
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Reset Mode | Auto |
Enclosure | Engineering Grade ABS Virgin Material |
- Pump sets of Farms, Rivers and Wells
- Suitable for Semi Automatic Star-Delta Starter
AUTO SWITCH
SMART AUTOSWITCH (WTF-RF)
- Provide Auto Correct Phase Sequence System
- Automatically start the Motor
- Single Phasing Protection
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Suitable for DOL & FASD Starter
- Each Phase LED indications
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Switching Device | Relay |
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Reset Mode | Auto |
Enclosure | ABS virgin material |
- Pump sets of Farms, Rivers and Wells
- Suitable for DOL and FASD starter
AUTO SWITCH
DIGITAL AUTOSWITCH (UNIVERSAL)
- Automatically start the Motor
- Starting Time Delay (0.5 to 10Min) Adjustable
- Provide Overload & Dry run Protection(Auto/Manual)
- Available in variable current range
- Digital V&A meter
- Provide On-Off Timer Facility
- With High & Low Voltage Cut off
- Easy to set parameters using set, up and shift key
- Single Phasing Protection
- Reverse Phasing Protection
- Suitable for any HP / KW rating Pumps
- Suitable for DOL & FASD Starter
- LED indications
- Digital Display Indication
- Auto / manual switch
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Current Range | 6-40A, 30-150A, 20-100A |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 0.5Min to 10Min (Adjustable) |
Reset Mode | Auto |
Enclosure | Engineering Grade ABS Material |
- Pump sets of Farms, Rivers and Wells
- DOL and FASD Submersible starter.
AUTO SWITCH
MOBILE AUTOSWITCH
- Operate the Motor from anywhere in the world
- Users will get the current status of the motor by call(voice feedback) and SMS
- Whenever Power is coming back, GSM auto switch ringing to farmer’s phone and give information
- When Fault occur, system call immediately to users mobile and inform about fault such as dry run, overload, under voltage and damage conductor of Motor
- To Inform Current of any one phase via call and SMS
- Available in Three Languages (English, Hindi, Gujarati)
- Automatically start the Motor
- Protection against Phase failure and Reverse Phasing
- Suitable for any HP / KW rating Pumps
- LED indications
- Auto / manual Facility
System Voltage | 415 VAC ± 20%, 50HZ |
---|---|
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Unbalanced Trip setting | 45V ± 5V |
Tripping Time | 2 sec |
On time Delay | 1 Min |
Reset Mode | Manual |
Enclosure | Engineering Grade ABS Material |
- Pump sets of Farms, Rivers and Wells
- Suitable for DOL and FASD starter.
AUTO SWITCH
SINGLE PHASE AUTOSWITCH (JSA)
- Automatically start the Motor
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Suitable For Single Phase Submersible Starter
- LED indications
- Auto / manual switch
System Voltage | 230 VAC ± 20%, 50HZ |
---|---|
Output Relay contact | 1NO |
Output contact rating | 6Amp, 240 VAC (resistive) |
Output Relay Contact for Start Capacitor | 30Amp, 240VAC |
On time Delay | 1 Min |
Enclosure | ABS Material |
- Pump sets of Farms, Rivers and Wells
- Single Phase Submersible starter.
AUTO SWITCH
SINGLE PHASE AUTOSWITCH (JSA-MINI)
- Automatically start the Motor
- 1 minute of ON Time Delay
- Suitable for any HP / KW rating Pumps
- Suitable For Single Phase Submersible Starter
- LED indications
- Auto / manual switch
System Voltage | 230 VAC ± 20%, 50HZ |
---|---|
Switching Device | Relay |
Output Relay contact | 1NO |
Output Relay Contact for NV coil | 6Amp, 240 VAC (resistive) |
Output Relay Contact for Start Capacitor | 6Amp, 240VAC |
On time Delay | 1 Min |
Enclosure | ABS Material |
- Pump sets of Farms, Rivers and Wells
- Single Phase Submersible starter.