images
AUTO SWITCH

MINI AUTOSWITCH (WTF)

  • Automatically start the Motor
  • Single Phasing Protection
  • Reverse Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Suitable for DOL & FASD Starter
  • LED indications
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Resetting Auto Reset
Enclosure ABS Material
  • Pump sets of Farms, Rivers and Wells
  • Suitable for DOL and FASD starter.
images
AUTO SWITCH

AUTOSWITCH (WTF)

  • Automatically start the Motor
  • Single Phasing Protection
  • Reverse Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Suitable for DOL & FASD Starter
  • LED indications
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Resetting Auto Reset
Enclosure ABS Material
  • Pump sets of Farms, Rivers and Wells
  • Suitable for DOL and FASD starter.
images
AUTO SWITCH

AUTOSWITCH (WTF-RF)

  • Provide Auto Correct Phase Sequence System
  • Automatically start the Motor
  • Single Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Suitable for DOL & FASD Starter
  • Each Phase LED indications
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Switching Device Relay
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Reset Mode Auto
Enclosure Engineering Grade ABS virgin material
  • Pump sets of Farms, Rivers and Wells.
  • Suitable for DOL and FASD starter.
images
AUTO SWITCH

AUTOSWITCH (WTS-RF)

  • Microcontroller based Technology
  • Specially for Oil Filled Bentex Starter (9 wires)
  • Provide Auto Correct Phase Sequence System
  • Automatically start the Motor
  • Single Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Each Phase LED indications
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Switching Device Relay
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Reset Mode Auto
Enclosure ABS Virgin Material
  • Pump sets of Farms, Rivers and Wells
  • Oil Filled Bentex Starter Of Agriculture Pump.
images
AUTO SWITCH

AUTOSWITCH (WDS)

  • Specially for Semi Automatic Star Delta Starter
  • Automatically start the Motor
  • Single Phasing Protection
  • Reverse Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • LED indications
  • Auto / manual switch
System Voltage 415VAC instead of 230VAC
Switching Device Relay
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Reset Mode Auto
Enclosure ABS Material
  • Pump sets of Farms, Rivers and Wells
  • Suitable for Semi Automatic Star Delta Starter
images
AUTO SWITCH

AUTOSWITCH (WDS-RF)

  • Specially for Semi Automatic Star-Delta Starter
  • Provide Auto Correct Phase Sequence System
  • Automatically start the Motor
  • Single Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Each Phase LED indications
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Switching Device Relay
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Reset Mode Auto
Enclosure Engineering Grade ABS Virgin Material
  • Pump sets of Farms, Rivers and Wells
  • Suitable for Semi Automatic Star-Delta Starter
images
AUTO SWITCH

SMART AUTOSWITCH (WTF-RF)

  • Provide Auto Correct Phase Sequence System
  • Automatically start the Motor
  • Single Phasing Protection
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Suitable for DOL & FASD Starter
  • Each Phase LED indications
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Switching Device Relay
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Reset Mode Auto
Enclosure ABS virgin material
  • Pump sets of Farms, Rivers and Wells
  • Suitable for DOL and FASD starter
images
AUTO SWITCH

DIGITAL AUTOSWITCH (UNIVERSAL)

  • Automatically start the Motor
  • Starting Time Delay (0.5 to 10Min) Adjustable
  • Provide Overload & Dry run Protection(Auto/Manual)
  • Available in variable current range
  • Digital V&A meter
  • Provide On-Off Timer Facility
  • With High & Low Voltage Cut off
  • Easy to set parameters using set, up and shift key
  • Single Phasing Protection
  • Reverse Phasing Protection
  • Suitable for any HP / KW rating Pumps
  • Suitable for DOL & FASD Starter
  • LED indications
  • Digital Display Indication
  • Auto / manual switch
System Voltage 415 VAC ± 20%, 50HZ
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Current Range 6-40A, 30-150A, 20-100A
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 0.5Min to 10Min (Adjustable)
Reset Mode Auto
Enclosure Engineering Grade ABS Material
  • Pump sets of Farms, Rivers and Wells
  • DOL and FASD Submersible starter.
images
AUTO SWITCH

MOBILE AUTOSWITCH

  • Operate the Motor from anywhere in the world
  • Users will get the current status of the motor by call(voice feedback) and SMS
  • Whenever Power is coming back, GSM auto switch ringing to farmer’s phone and give information
  • When Fault occur, system call immediately to users mobile and inform about fault such as dry run, overload, under voltage and damage conductor of Motor
  • To Inform Current of any one phase via call and SMS
  • Available in Three Languages (English, Hindi, Gujarati)
  • Automatically start the Motor
  • Protection against Phase failure and Reverse Phasing
  • Suitable for any HP / KW rating Pumps
  • LED indications
  • Auto / manual Facility
System Voltage 415 VAC ± 20%, 50HZ
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Unbalanced Trip setting 45V ± 5V
Tripping Time 2 sec
On time Delay 1 Min
Reset Mode Manual
Enclosure Engineering Grade ABS Material
  • Pump sets of Farms, Rivers and Wells
  • Suitable for DOL and FASD starter.
images
AUTO SWITCH

SINGLE PHASE AUTOSWITCH (JSA)

  • Automatically start the Motor
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Suitable For Single Phase Submersible Starter
  • LED indications
  • Auto / manual switch
System Voltage 230 VAC ± 20%, 50HZ
Output Relay contact 1NO
Output contact rating 6Amp, 240 VAC (resistive)
Output Relay Contact for Start Capacitor 30Amp, 240VAC
On time Delay 1 Min
Enclosure ABS Material
  • Pump sets of Farms, Rivers and Wells
  • Single Phase Submersible starter.
images
AUTO SWITCH

SINGLE PHASE AUTOSWITCH (JSA-MINI)

  • Automatically start the Motor
  • 1 minute of ON Time Delay
  • Suitable for any HP / KW rating Pumps
  • Suitable For Single Phase Submersible Starter
  • LED indications
  • Auto / manual switch
System Voltage 230 VAC ± 20%, 50HZ
Switching Device Relay
Output Relay contact 1NO
Output Relay Contact for NV coil 6Amp, 240 VAC (resistive)
Output Relay Contact for Start Capacitor 6Amp, 240VAC
On time Delay 1 Min
Enclosure ABS Material
  • Pump sets of Farms, Rivers and Wells
  • Single Phase Submersible starter.