images
Single Phase Electronics Starter

JSC-120

  • Overload Protection
  • High voltage Protection
  • Low Voltage Protection
  • Available in variable current Range
  • Easy to set O/L setting
  • LED indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp, 10-30Amp
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, H/V, L/V, O/L
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools
images
Single Phase Electronics Starter

JSC-A-120

  • Auto Start with On Time Delay Facility
  • Overload Protection
  • High voltage Protection
  • Low Voltage Protection
  • Easy to set O/L setting
  • Auto/Manual Start Facility
  • LED Indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp, 10-30Amp
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
On Time Delay 1 min
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, H/V, L/V, O/L
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools
images
Single Phase Electronics Starter

JSC-DG

  • Microcontroller Based Technology
  • Digital Volt /Amp Meter
  • Overload Protection
  • High voltage Protection
  • Low Voltage Protection
  • Easy to set O/L setting using adjustable knob
  • LED Indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, O/L
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools
images
Single Phase Electronics Starter

OLS

  • Microcontroller Based Technology
  • Digital Volt /Amp Meter
  • Overload Protection
  • High voltage Protection
  • Low Voltage Protection
  • Easy to set O/L current by SET Key
  • Auto/Manually Start Facility
  • LED Indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, O/L,H/L, Delay
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools
images
Single Phase Electronics Starter

OLS-T

  • Microcontroller Based Technology
  • Digital Volt /Amp Meter
  • OFF Timer Facility
  • Overload Protection
  • High voltage Protection
  • Low Voltage Protection
  • Easy to set O/L & OFF Timer by adjustable knob
  • LED Indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp
OFF Time 1Min to 180Min
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, O/L, OFF Timer
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools
images
Single Phase Electronics Starter

DLS

  • Microcontroller Based Technology
  • Digital Volt /Amp Meter
  • Dry Run Protection
  • Overload Protection
  • Available in Variable Current Range
  • High voltage Protection
  • Low Voltage Protection
  • Easy to set O/L & D/R by SET key
  • Auto/Manually Start Facility
  • LED Indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, O/L,H/L, Delay
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools
images
Single Phase Electronics Starter

DLS-T

  • Microcontroller Based Technology
  • Digital Volt /Amp Meter
  • OFF Timer Facility
  • Dry Run Protection
  • Overload Protection
  • High voltage Protection
  • Low Voltage Protection
  • Easy to set O/L, D/R, OFF Timer by adjustable knob
  • LED Indication
System Voltage 230 VAC ± 20%, 50HZ
Operating Voltage 140V to 285V
Current Range 2-20Amp, 1-10Amp
OFF Time 1Min to 180Min
Under Voltage 130V Cut Off – 140V Cut In
Over Voltage 280V Cut Off – 270V Cut In
Switching Device Relay
On-Off/Reset By Manual Push Button
Indication Motor On, O/L, OFF Timer
Enclosure ABS Material
  • Air Conditioner
  • Atta Maker
  • Mono Block Electric Motor
  • Pressure Pump
  • Machine tools